CR 1212 1
Chapter 1
Chapter 2
Chapter 3
Chapter 4
What is the CR 1212 and How Does It Work?
Section A: What is the CR 1212?
Section B: How the CR 1212 Works
Section C: Commands: Controlling the Tablet’s Operation
Section D: Alternative Configurations
Assembly and Installation
Interfacing with the Host
Section A: Hardware Interfaces
Section B: Baud Rate
Section C: Communication Protocols
Section D: Report Formats
Operating Characteristics and Functions
Section A: Controlling the Report Flow
Point Mode
Remote Request Mode
Stream Mode
Switch Stream Mode
Report Rate
Increment Mode
Section B: Setting the Resolution
Resolution, Predefined
Resolution, Definable (Set X, Y Scale)
Section C: Other Functions
Bit Pad Configuration
Origin
Relative Coordinates (Delta Mode)
Reset (to Default Operating Characteristics)
Send Configuration
3
3
4
6
6
7
10
10
11
11
12
16
16
17
17
18
18
19
19
22
23
24
27
27
27
28
28
29
Vista de página 0
1 2 3 4 5 6 ... 49 50

Resumo do Conteúdo

Página 1

CR 1212 1 Chapter 1 Chapter 2 Chapter 3 Chapter 4 What is the CR 1212 and How Does It Work? Section A: What is the C

Página 2

CR 1212 10 Chapter 3: Interfacing with the Host For successful communication between the CR 1212 and its host, they must have the same hardware

Página 3

CR 1212 11 RS-232C Signal Levels NOTE: The source is the EIA Standard RS-232C: Interface between Data Terminal Equipment and Data Communicatio

Página 4

CR 1212 12 Section D: Report Formats The CR 1212 has one of the following report formats:  Bit Pad One-compatible format (default)  Bit Pad

Página 5

CR 1212 13 Bit Pad Two-Compatible Report Format CR Report Format

Página 6

CR 1212 14 Bit Pad One- or Two-compatible format for Relative Coordinates CR Format for Relative Coordinates Key:  LSB is the least signifi

Página 7

CR 1212 15 *Output for Bit Pad One or Two configurations using absolute coordinates. **Output for Bit Pad One or Two configurations using rela

Página 8

CR 1212 16 Chapter 4: Operating Characteristics and Functions The CR 1212 includes a variety of operating characteristics and functions that ca

Página 9

CR 1212 17 A report issued when the stylus/cursor is out-of-prox is always the last in-prox scanned report. Because the last scanned report ma

Página 10

CR 1212 18 Stream Mode In Stream Mode, the graphics tablet issues reports continuously, whether a stylus/cursor button is pressed or not. The

Página 11

CR 1212 19 Report Rate The Report Rate function is an adjunct to Stream and Switch Stream modes. Use Report Rate to define the number of rep

Página 12

CR 1212 2 Chapter 5 Chapter 6 Chapter 7 Chapter 8 Appendix A Appendix B Tablet Beep Transmission Control Section D: Reserved

Página 13

CR 1212 20 NOTE: When using Increment Mode, it’s recommended to use a resolution setting of 50 lpi or higher. How Increment Mode Works The last

Página 14

CR 1212 21 The points issued are: How to Use Increment Mode Send the mode command and then the increment value. The increment value is in cou

Página 15

CR 1212 22 Combining Increment Mode with Other Modes  Point Mode and Increment Mode: The stylus/cursor location, at the time Increment Mode

Página 16

CR 1212 23 Bit Pad One and Two Configurations: The tablet can have a resolution of up to 508 lpi (6096 counts over a 12-inch axis). Bit Pad co

Página 17

CR 1212 24 Use these commands to set the tablet to one of the predefined resolutions listed about. (Resolution is restricted in Bit Pad One an

Página 18

CR 1212 25 37 lpi x 12 inches = 444 … is the desired axis resolution  The other device may have a resolution expressed as the overall axis

Página 19

CR 1212 26 67 x 12 inches = 804 … is the desired X axis resolution 86 x 12 inches = 1032 … is the desired Y axis resolution 2. Convert the des

Página 20

CR 1212 27 Section C: Other Functions Bit Pad Configuration If the unit’s hardware configuration is Bit Pad, you can adjust between Bit Pad

Página 21

CR 1212 28 Relative Coordinates (Delta Mode) The tablet defaults to an absolute coordinate system. This command changes it to a relative coor

Página 22

CR 1212 29 Send Configuration Send Configuration issues a report to the host that identifies the resolution of each axis. The report format i

Página 23

CR 1212 3 Chapter 1: What is the CR 1212 and How Does It Work? Section A: What is the CR 1212? CR 1212 is a graphics tablet that acts as an inp

Página 24

CR 1212 30 Key: LSB MSB b0 Least significant bit Most significant bit Maximum X or Y value at set resolution The configuration report does not

Página 25

CR 1212 31 Transmission Control The Stop Transmission and Resume Transmission commands act as software gates, controlling data transmission fr

Página 26

CR 1212 32 Chapter 5: Guidelines for Writing a Device Driver For the computer to make use of the data being sent to it from the tablet, the sof

Página 27

CR 1212 33 The following flowcharts are for a CR 1212 in the Bit Pad One configuration. Configure Host and Tablet  Structure the host communi

Página 28

CR 1212 34 Report Collection – Interrupt Routines  Assemble the report: collect the report’s data bytes into an array  Check for errors

Página 29

CR 1212 35 Cont.

Página 30

CR 1212 36 Process Reports from the Tablet  Decode the report  Filter reports, if required by the application  Notify the application, if

Página 31

CR 1212 37 Chapter 6: Using the CR 1212 Follow these guidelines to maximize usage of the CR 1212.  You can tape things down to the tablet, in

Página 32

CR 1212 38  Cursor is most accurate when held parallel with the tablet surface. To activate a cursor button, press it.  The tablet beeps

Página 33

CR 1212 39 Chapter 7: Checking the Graphics Tablet Section A: Tablet Calibration The tablet calibrates each time it’s turned on. The calibrati

Página 34

CR 1212 4 Section B: How the CR 1212 Works CR 1212 translates the stylus/cursor position on the tablet into digital information and communicate

Página 35

CR 1212 40 The X and Y coordinates should increase as you slide the stylus/cursor up and right, as shown below.

Página 36

CR 1212 41 Section D: Diagnostic Functions Echo Use Echo to ensure that the interface between the tablet and host is operating correctly. The

Página 37 - Chapter 6: Using the CR 1212

CR 1212 42 CR Configuration: Self-Test Report A D PR CA T Analog circuitry test; pass = 1, fail = 0 Digital circuitry test; pass = 1, fai

Página 38

CR 1212 43 Chapter 8: Operating Environment, Care and Service Section A: Operating Environment Operate the CR 1212 within these temperature and

Página 39

CR 1212 44 When contacting Customer Service, please have ready the unit serial number. The serial number is located on the bottom of the table

Página 40

CR 1212 45 Section D: Changing the Stylus Refill To change the stylus refill, grasp the refill by the tip and pull straight out. Since the tip

Página 41

CR 1212 46 Appendix A Specifications Physical Description Approximate physical dimensions: Width Length Maximum Height Weight 16 inches (406 m

Página 42

CR 1212 47 Appendix B ASCII Conversion Chart

Página 43

CR 1212 48

Página 44

CR 1212 49

Página 45

CR 1212 5 As previously stated, reports are measured in counts of resolution. As shown below, each square is one count of resolution. The tab

Página 46 - Appendix A Specifications

CR 1212 50 Corporate Headquarters 14557 N. 82nd Street Scottsdale, Arizona 85260 Tel: 1-866-746-3015 Support: 1-866-746-3015 Fax: 480-998-1

Página 47 - CR 1212 47

CR 1212 6 Reports are in absolute or relative coordinates. Absolute coordinates are coordinates measured from the tablet’s origin (0, 0). Rel

Página 48 - CR 1212 48

CR 1212 7 Chapter 2: Assembly and Installation The CR 1212 package should include the following:  Tablet  Stylus or cursor  Interface cab

Página 49

CR 1212 8 The cursor and stylus are interchangeable. However, before changing from one to the other, turn off the tablet. (This allows the ta

Página 50

CR 1212 9 4. Plug the power supply barrel connector into the interface cable’s D connector. 5. Plug the power supply into a grounded electri

Comentários a estes Manuais